WI-130 Batching System
This system controls a four
ingredient, two-speed batching system. Storage is provided for 500 formulas,
each with four ingredients. A batch report is available to print up to 500 completed
batch transactions from the transaction database. Prior to operating the
system, ingredients, tolerances, and formulas must be setup. Each ingredient
has a set of auto-adjusting preact parameters, a tolerance range, high speed
target, and dribble speed target. To begin a batch, the
operator presses the BATCH key. The system prompts for a formula number. After
entering the desired formula, various information about the formula is
displayed on the screen. If the formula is correct,
the operator enters the size batch to run. To run a full size batch, a value of
100 should be entered. If a half size batch is desired, enter a value of 50. The system tares the scale
and begins batching the first ingredient. Once the target for the first
ingredient is reached, the supply valve is closed. The batch cycle continues
for each of the four ingredients. Once the batch is complete, the system saves
the ingredient information for use in the report. The system will then dump the
batch until the weight of the scale drops below the empty threshold. To print the transaction
report, which lists all completed batches stored in the system, the operator
presses the REPORT key. Other reports available include a formula list and an
ingredient list. |