WI-130 Three Scale
Weighing System
This system utilizes three
scales to weigh various size boxes as they are filled. Weighing is done on
individual scales, or a combination of scales. The following weighing
configurations are available: Scale A Only Scale B Only Scale C Only Scale A & B Scale B & C Scale A & B & C The operator will approach
the WI-130, and press the function key corresponding to the scale being used
(ex. A, B, C, A/B, B/C, A/B/C). After pressing the desired
key, the system prompts for an Operator ID and a Tare Weight. The display then
changes to the Net Weighing mode. The operator fills the box and presses the
PRINT key when finished. The system captures the
weight from the scale, and transmits the data to a wedge attached to a PC. During
the weighing operation, the scale keys are locked and will only function again
after the PRINT key is pressed. Conversely, the PRINT key will be locked until
one of the scale keys has been selected. This prevents the current weighing
operation from being overwritten by another operator, and prevents an invalid
weight transaction from being sent to the PC. |